Logistic centre Erfurt

Blower Door Test

Location: Erfurt

Read more

[Translate to English:] Logistikzentrum Erfurt

Project volume:
Blower Door World Record 14. April 2013
Logistic warehouse Erfurt consists of 5 individual halls / fire compartments

Facts:
192m x 528m x 13,5m in the centre (width x length x height)

Net floor space:
101.376 m²

Building volume:
221.904 m²

Net volume:
1.346.746 m³

Scope of performance:
Blower Door Test as per Din EN 13829
Leakage detection as per DIN EN 13829
Volume calculation as per DIN EN 13829 as well as DIN 277
Calculation of the building volume as per DIN EN 13829

Applied measurement technology:
BlowerDoor Multiple Fan
Infiltec G54
Entire building preparation of the cerfication tests as per EnEV

Categories: Industry, trade & public buildings
created at: